On Wed, Jun 13, 2012 at 12:41 AM,  <alain.mou...@bull.net> wrote:
> Hi
>
> I tried to make a Pacemaker/cman stack working following the instructions
> here :
> (on Red-Hat 6.2)
>
> So I stopped corosync and Pacemaker
> I remove the corosync.conf
> (and there were no /etc/corosync/service/pcmk file)
>
> I've patched the cman.conf :
> sed -i.sed "s/.*CMAN_QUORUM_TIMEOUT=.*/CMAN_QUORUM_TIMEOUT=0/g"
> /etc/sysconfig/cman
>
> I create the /etc/cluster/cluster.conf (and put it on both nodes chili2 &
> chili3):
> <?xml version="1.0"?>
> <cluster config_version="1" name="chili2_chili3">
>  <logging debug="off"/>
>    <clusternodes>
>        <clusternode name="chili2" nodeid="1">
>           <fence>
>               <method name="pcmk-redirect">
>                  <device name="pcmk" port="chili2"/>
>               </method>
>           </fence>
>        </clusternode>
>        <clusternode name="chili3" nodeid="2">
>            <fence>
>                <method name="pcmk-redirect">
>                   <device name="pcmk" port="chili3"/>
>                </method>
>            </fence>
>        </clusternode>
>      </clusternodes>
>      <fencedevices>
>         <fencedevice name="pcmk" agent="fence_pcmk"/>
>       </fencedevices>
> </cluster>
>
> but when I start cman, all daemon start  successfully,
> Starting cluster:
>   Checking if cluster has been disabled at boot...        [  OK  ]
>   Checking Network Manager...                             [  OK  ]
>   Global setup...                                         [  OK  ]
>   Loading kernel modules...                               [  OK  ]
>   Mounting configfs...                                    [  OK  ]
>   Starting cman...                                        [  OK  ]
>   Waiting for quorum...                                   [  OK  ]
>   Starting fenced...                                      [  OK  ]
>   Starting dlm_controld...                                [  OK  ]
>   Starting gfs_controld...                                [  OK  ]
>   Unfencing self...                                       [  OK  ]
>   Joining fence domain...                                 [  OK  ]
> and I got :
> cman_tool nodes
> Node  Sts   Inc   Joined               Name
>   1   M     16   2012-06-12 15:20:53  chili2
>   2   M     20   2012-06-12 15:30:27  chili3
>
>  but :
> crm_mon -1
> Connection to cluster failed: connection failed
>
> I can't find what I have missed ...

service pacemaker start :-)

> Except if it is not expected to work on 6.2 ?
>
> I have installed the following rpms :
> openais-1.1.1-7.bl6.x86_64.rpm
> openaislib-1.1.1-7.bl6.x86_64.rpm
> modcluster-0.16.2-10.bl6.x86_64.rpm
> ricci-0.16.2-35.bl6.x86_64.rpm
> fence-virtd-checkpoint-0.2.1-8.bl6.x86_64.rpm
> fence-virtd-multicast-0.2.1-8.bl6.x86_64.rpm
> fence-virtd-0.2.1-8.bl6.x86_64.rpm
> fence-virt-0.2.1-8.bl6.x86_64.rpm
> (but not gfs2 and ocfs2 as I don't need them)
>
> Thanks for help
> Alain
> _______________________________________________
> Linux-HA mailing list
> Linux-HA@lists.linux-ha.org
> http://lists.linux-ha.org/mailman/listinfo/linux-ha
> See also: http://linux-ha.org/ReportingProblems
_______________________________________________
Linux-HA mailing list
Linux-HA@lists.linux-ha.org
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems

Reply via email to