On 29. 04. 25 8:59 odp., Jakub Kicinski wrote:
On Fri, 25 Apr 2025 19:09:31 +0200 Ivan Vecera wrote:
+static int zl3073x_devlink_info_get(struct devlink *devlink,
+ struct devlink_info_req *req,
+ struct netlink_ext_ack *extack)
+{
+ struct zl3073x_dev *zldev = devlink_priv(devlink);
+ u16 id, revision, fw_ver;
+ char buf[16];
+ u32 cfg_ver;
+ int rc;
+
+ rc = zl3073x_read_u16(zldev, ZL_REG_ID, &id);
+ if (rc)
+ return rc;
+
+ snprintf(buf, sizeof(buf), "%X", id);
+ rc = devlink_info_version_fixed_put(req,
+
DEVLINK_INFO_VERSION_GENERIC_ASIC_ID,
+ buf);
+ if (rc)
+ return rc;
+
+ rc = zl3073x_read_u16(zldev, ZL_REG_REVISION, &revision);
+ if (rc)
+ return rc;
+
+ snprintf(buf, sizeof(buf), "%X", revision);
+ rc = devlink_info_version_fixed_put(req,
+
DEVLINK_INFO_VERSION_GENERIC_ASIC_REV,
+ buf);
+ if (rc)
+ return rc;
+
+ rc = zl3073x_read_u16(zldev, ZL_REG_FW_VER, &fw_ver);
+ if (rc)
+ return rc;
+
+ snprintf(buf, sizeof(buf), "%u", fw_ver);
+ rc = devlink_info_version_fixed_put(req,
+ DEVLINK_INFO_VERSION_GENERIC_FW,
Are you sure FW version is fixed? Fixed is for unchangeable
properties like ASIC revision or serial numbers.
Hmm, should be running. Thanks for pointing out.
+ buf);
+ if (rc)
+ return rc;
+
+ rc = zl3073x_read_u32(zldev, ZL_REG_CUSTOM_CONFIG_VER, &cfg_ver);
+ if (rc)
+ return rc;
+
+ /* No custom config version */
+ if (cfg_ver == U32_MAX)
+ return 0;
+
+ snprintf(buf, sizeof(buf), "%lu.%lu.%lu.%lu",
+ FIELD_GET(GENMASK(31, 24), cfg_ver),
+ FIELD_GET(GENMASK(23, 16), cfg_ver),
+ FIELD_GET(GENMASK(15, 8), cfg_ver),
+ FIELD_GET(GENMASK(7, 0), cfg_ver));
+
+ return devlink_info_version_running_put(req, "cfg.custom_ver", buf);
You need to document the custom versions and properties in a driver
specific file under Documentation/networking/device_drivers/
Will add.
Thanks for the review, Jakub.
Ivan