Make sure that an out-of-bounds read doesn't occur in the Sixaxis battery level
lookup table in the event that the controller sends an invalid battery status
value in the report.

Signed-off-by: Frank Praznik <[email protected]>
---
 drivers/hid/hid-sony.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/hid/hid-sony.c b/drivers/hid/hid-sony.c
index a51a9c0..b39e3ab 100644
--- a/drivers/hid/hid-sony.c
+++ b/drivers/hid/hid-sony.c
@@ -854,7 +854,8 @@ static void sixaxis_parse_report(struct sony_sc *sc, __u8 
*rd, int size)
                battery_capacity = 100;
                battery_charging = !(rd[30] & 0x01);
        } else {
-               battery_capacity = sixaxis_battery_capacity[rd[30]];
+               __u8 index = rd[30] <= 5 ? rd[30] : 5;
+               battery_capacity = sixaxis_battery_capacity[index];
                battery_charging = 0;
        }
        cable_state = !((rd[31] >> 4) & 0x01);
-- 
1.8.5.3

--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html