On Thu, Jan 30, 2014 at 10:48 AM, Jason Gerecke <killert...@gmail.com> wrote:
> Some tablet PC sensors (e.g. the 0xEC found in the Thinkpad
> Yoga) report more than 256 pressure levels and will experience
> wraparound unless the full range is read.
>
> Signed-off-by: Jason Gerecke <killert...@gmail.com>
> ---
>  drivers/input/tablet/wacom_wac.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/input/tablet/wacom_wac.c 
> b/drivers/input/tablet/wacom_wac.c
> index 9ff5613..ae1437b 100644
> --- a/drivers/input/tablet/wacom_wac.c
> +++ b/drivers/input/tablet/wacom_wac.c
> @@ -1087,7 +1087,7 @@ static int wacom_tpc_pen(struct wacom_wac *wacom)
>                 input_report_key(input, BTN_STYLUS2, data[1] & 0x10);
>                 input_report_abs(input, ABS_X, le16_to_cpup((__le16 
> *)&data[2]));
>                 input_report_abs(input, ABS_Y, le16_to_cpup((__le16 
> *)&data[4]));
> -               input_report_abs(input, ABS_PRESSURE, ((data[7] & 0x01) << 8) 
> | data[6]);
> +               input_report_abs(input, ABS_PRESSURE, ((data[7] & 0x03) << 8) 
> | data[6]);
>                 input_report_key(input, BTN_TOUCH, data[1] & 0x05);
>                 input_report_key(input, wacom->tool[0], prox);
>                 return 1;
> --
> 1.8.5.3
>
Tested-by: Aaron Skomra <aaron.sko...@wacom.com>
--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html