Hi Rui, Eduardo,

On Wed, Dec 30, 2015 at 01:13:02PM +0800, Leo Yan wrote:
> When calculate temperature, old code firstly do division and then
> convert to "millicelsius" unit. This will lose resolution and only can
> read back temperature with "Celsius" unit.
> 
> So firstly scale step value to "millicelsius" and then do division, so
> finally we can increase resolution for temperature value. Also refine
> the calculation from temperature value to step value.
> 
> Signed-off-by: Leo Yan <[email protected]>

Could you help merge this patch?

Thanks,
Leo Yan

> ---
>  drivers/thermal/hisi_thermal.c | 4 ++--
>  1 file changed, 2 insertions(+), 2 deletions(-)
> 
> diff --git a/drivers/thermal/hisi_thermal.c b/drivers/thermal/hisi_thermal.c
> index 36d0729..5e820b5 100644
> --- a/drivers/thermal/hisi_thermal.c
> +++ b/drivers/thermal/hisi_thermal.c
> @@ -68,12 +68,12 @@ static inline int _step_to_temp(int step)
>        * Every step equals (1 * 200) / 255 celsius, and finally
>        * need convert to millicelsius.
>        */
> -     return (HISI_TEMP_BASE + (step * 200 / 255)) * 1000;
> +     return (HISI_TEMP_BASE * 1000 + (step * 200000 / 255));
>  }
>  
>  static inline long _temp_to_step(long temp)
>  {
> -     return ((temp / 1000 - HISI_TEMP_BASE) * 255 / 200);
> +     return ((temp - HISI_TEMP_BASE * 1000) * 255) / 200000;
>  }
>  
>  static long hisi_thermal_get_sensor_temp(struct hisi_thermal_data *data,
> -- 
> 1.9.1
> 