On Tuesday 31 May 2016 02:56 PM, Axel Lin wrote:
According to the datasheet:SLEW Register(Address = 07h) b7 b6 b5 b4 b3 b2 b1 b0 48mV/us 42mV/us 36mV/us 30mV/us 24mV/us 18mV/us 12mV/us 6mV/us Current code does not set correct slew rate in some cases: e.g. Assume ramp_delay is 10000, current code sets slew register to 6mV/us. Fix the logic to set slew register.
Setting register to nearest faster ramp side, the change looks fine. Acked-by: Laxman Dewangan <[email protected]>