> Replace the code that guarantees the device stays in direct mode
> with iio_device_claim_direct_mode() which does same.  This allows
> removal of an unused lock in the device private global data.

Acked-by: Peter Meerwald-Stadler <[email protected]>
 
> Signed-off-by: Alison Schofield <[email protected]>
> Cc: Daniel Baluta <[email protected]>
> ---
>  drivers/iio/light/tcs3414.c | 12 +++++-------
>  1 file changed, 5 insertions(+), 7 deletions(-)
> 
> diff --git a/drivers/iio/light/tcs3414.c b/drivers/iio/light/tcs3414.c
> index f90f8c5..8a15fb5 100644
> --- a/drivers/iio/light/tcs3414.c
> +++ b/drivers/iio/light/tcs3414.c
> @@ -53,7 +53,6 @@
>  
>  struct tcs3414_data {
>       struct i2c_client *client;
> -     struct mutex lock;
>       u8 control;
>       u8 gain;
>       u8 timing;
> @@ -134,16 +133,16 @@ static int tcs3414_read_raw(struct iio_dev *indio_dev,
>  
>       switch (mask) {
>       case IIO_CHAN_INFO_RAW:
> -             if (iio_buffer_enabled(indio_dev))
> -                     return -EBUSY;
> -             mutex_lock(&data->lock);
> +             ret = iio_device_claim_direct_mode(indio_dev);
> +             if (ret)
> +                     return ret;
>               ret = tcs3414_req_data(data);
>               if (ret < 0) {
> -                     mutex_unlock(&data->lock);
> +                     iio_device_release_direct_mode(indio_dev);
>                       return ret;
>               }
>               ret = i2c_smbus_read_word_data(data->client, chan->address);
> -             mutex_unlock(&data->lock);
> +             iio_device_release_direct_mode(indio_dev);
>               if (ret < 0)
>                       return ret;
>               *val = ret;
> @@ -288,7 +287,6 @@ static int tcs3414_probe(struct i2c_client *client,
>       data = iio_priv(indio_dev);
>       i2c_set_clientdata(client, indio_dev);
>       data->client = client;
> -     mutex_init(&data->lock);
>  
>       indio_dev->dev.parent = &client->dev;
>       indio_dev->info = &tcs3414_info;
> 

-- 

Peter Meerwald-Stadler
+43-664-2444418 (mobile)

Reply via email to