Hi Linus,

please pull from the 'for-linus' branch of

        git://git.kernel.org/pub/scm/linux/kernel/git/s390/linux.git for-linus

to receive the following updates:

Two more bugs fixes for 4.7:
- A KVM regression introduced with the pgtable.c code split
- A perf issue with two hardware PMUs using a shared event context

Christian Borntraeger (1):
      KVM: s390/mm: Fix CMMA reset during reboot

Hendrik Brueckner (1):
      s390/cpum_cf: use perf software context for hardware counters

 arch/s390/kernel/perf_cpum_cf.c | 8 ++------
 arch/s390/mm/pgtable.c          | 2 +-
 2 files changed, 3 insertions(+), 7 deletions(-)

diff --git a/arch/s390/kernel/perf_cpum_cf.c b/arch/s390/kernel/perf_cpum_cf.c
index 59215c5..7ec63b1 100644
--- a/arch/s390/kernel/perf_cpum_cf.c
+++ b/arch/s390/kernel/perf_cpum_cf.c
@@ -649,6 +649,8 @@ static int cpumf_pmu_commit_txn(struct pmu *pmu)
 
 /* Performance monitoring unit for s390x */
 static struct pmu cpumf_pmu = {
+       .task_ctx_nr  = perf_sw_context,
+       .capabilities = PERF_PMU_CAP_NO_INTERRUPT,
        .pmu_enable   = cpumf_pmu_enable,
        .pmu_disable  = cpumf_pmu_disable,
        .event_init   = cpumf_pmu_event_init,
@@ -708,12 +710,6 @@ static int __init cpumf_pmu_init(void)
                goto out;
        }
 
-       /* The CPU measurement counter facility does not have overflow
-        * interrupts to do sampling.  Sampling must be provided by
-        * external means, for example, by timers.
-        */
-       cpumf_pmu.capabilities |= PERF_PMU_CAP_NO_INTERRUPT;
-
        cpumf_pmu.attr_groups = cpumf_cf_event_group();
        rc = perf_pmu_register(&cpumf_pmu, "cpum_cf", PERF_TYPE_RAW);
        if (rc) {
diff --git a/arch/s390/mm/pgtable.c b/arch/s390/mm/pgtable.c
index 4324b87..9f0ce0e 100644
--- a/arch/s390/mm/pgtable.c
+++ b/arch/s390/mm/pgtable.c
@@ -437,7 +437,7 @@ void ptep_zap_unused(struct mm_struct *mm, unsigned long 
addr,
        pgste = pgste_get_lock(ptep);
        pgstev = pgste_val(pgste);
        pte = *ptep;
-       if (pte_swap(pte) &&
+       if (!reset && pte_swap(pte) &&
            ((pgstev & _PGSTE_GPS_USAGE_MASK) == _PGSTE_GPS_USAGE_UNUSED ||
             (pgstev & _PGSTE_GPS_ZERO))) {
                ptep_zap_swap_entry(mm, pte_to_swp_entry(pte));