Sean,

On 07/21/2016 10:30 PM, Sean Paul wrote:
On Thu, Jul 21, 2016 at 9:14 AM, Yakir Yang <y...@rock-chips.com> wrote:
According to page 16 of Sharp LQ123P1JX31 datasheet, we need to add the
missing delay timing. Panel prepare time should be t1 (0.5ms~10ms) plus
t3 (0ms~100ms), and panel enable time should equal to t7 (0ms~50ms), and
panel unprepare time should be t11 (1ms~50ms) plus t12 (500ms~).

Signed-off-by: Yakir Yang <y...@rock-chips.com>
Reviewed-by: Sean Paul <seanp...@chromium.org>

Thanks  :-D

- Yakir

---
  drivers/gpu/drm/panel/panel-simple.c | 5 +++++
  1 file changed, 5 insertions(+)

diff --git a/drivers/gpu/drm/panel/panel-simple.c 
b/drivers/gpu/drm/panel/panel-simple.c
index 85143d1..f178998 100644
--- a/drivers/gpu/drm/panel/panel-simple.c
+++ b/drivers/gpu/drm/panel/panel-simple.c
@@ -1384,6 +1384,11 @@ static const struct panel_desc sharp_lq123p1jx31 = {
                 .width = 259,
                 .height = 173,
         },
+       .delay = {
+               .prepare = 110,
+               .enable = 50,
+               .unprepare = 550,
+       },
  };

  static const struct drm_display_mode shelly_sca07010_bfn_lnn_mode = {
--
1.9.1






Reply via email to