Hi

On Mon, Sep 26, 2016 at 3:55 PM, Fabio Estevam <feste...@gmail.com> wrote:
> On Mon, Sep 26, 2016 at 10:54 AM, Michael Trimarchi
> <mich...@amarulasolutions.com> wrote:
>
>>> Why don't you simply do like this?
>>>
>>>        reg_3p3v: regulator-3p3v {
>>>                compatible = "regulator-fixed";
>>>                regulator-name = "3P3V";
>>>                regulator-min-microvolt = <3300000>;
>>>                regulator-max-microvolt = <3300000>;
>>>        };
>>
>> Should dts rispect the schematic connection?
>
> Yes

So boot on and always on are used to declare their status and their
behavionr. I don't
see the point to not specify them in this way

Michael


-- 