3.2.84-rc1 review patch.  If anyone has any objections, please let me know.

------------------

From: Michael Walle <mich...@walle.cc>

commit b53893aae441a034bf4dbbad42fe218561d7d81f upstream.

According to the datasheet you should only write 1 to this bit. If it is
not set, at least AIN3 will return bad values on newer silicon revisions.

Fixes: d84ca5b345c2 ("hwmon: Add driver for ADT7411 voltage and temperature 
sensor")
Signed-off-by: Michael Walle <mich...@walle.cc>
Signed-off-by: Guenter Roeck <li...@roeck-us.net>
Signed-off-by: Ben Hutchings <b...@decadent.org.uk>
---
 drivers/hwmon/adt7411.c | 5 ++++-
 1 file changed, 4 insertions(+), 1 deletion(-)

--- a/drivers/hwmon/adt7411.c
+++ b/drivers/hwmon/adt7411.c
@@ -31,6 +31,7 @@
 
 #define ADT7411_REG_CFG1                       0x18
 #define ADT7411_CFG1_START_MONITOR             (1 << 0)
+#define ADT7411_CFG1_RESERVED_BIT3             (1 << 3)
 
 #define ADT7411_REG_CFG2                       0x19
 #define ADT7411_CFG2_DISABLE_AVG               (1 << 5)
@@ -291,8 +292,10 @@ static int __devinit adt7411_probe(struc
        mutex_init(&data->device_lock);
        mutex_init(&data->update_lock);
 
+       /* According to the datasheet, we must only write 1 to bit 3 */
        ret = adt7411_modify_bit(client, ADT7411_REG_CFG1,
-                                ADT7411_CFG1_START_MONITOR, 1);
+                                ADT7411_CFG1_RESERVED_BIT3
+                                | ADT7411_CFG1_START_MONITOR, 1);
        if (ret < 0)
                goto exit_free;
 

Reply via email to