On Fri, Nov 25, 2016 at 8:28 AM,  <[email protected]> wrote:
> From: Ondrej Jirman <[email protected]>
>
> When adjusting PLL_CPUX on H3, the PLL is temporarily driven
> too high, and the system becomes unstable (oopses or hangs).
>
> Add a notifier to avoid this situation by temporarily switching
> to a known stable 24 MHz oscillator.
>
> Signed-off-by: Ondrej Jirman <[email protected]>
> Tested-by: Lutz Sammer <[email protected]>

A Fixes tag would be nice. Otherwise,

Acked-by: Chen-Yu Tsai <[email protected]>