On Fri, Jan 06, 2017 at 06:48:31AM +0800, Icenowy Zheng wrote:
> 
> 2017年1月6日 06:04于 Maxime Ripard <[email protected]>写道:
> >
> > On Tue, Dec 27, 2016 at 12:25:15AM +0800, Icenowy Zheng wrote: 
> > > Add the H5 CCU clocks set based on the H3 one. 
> > > 
> > > Signed-off-by: Icenowy Zheng <[email protected]> 
> >
> > Is there any difference with H3's? 
> 
> One more Transport Stream controller, so one more bus gate and bus
> reset for it.

There's no need to duplicate more than 1000 lines of code just for
that then. Just add a new compatible and reuse the clocks already
defined.

Maxime

-- 
Maxime Ripard, Free Electrons
Embedded Linux and Kernel engineering
http://free-electrons.com

Attachment: signature.asc
Description: PGP signature

Reply via email to