On Fri 06-01-17 21:54:43, Fabian Frederick wrote:
> We were checking block number without checking partition.
> sbi->s_partmaps[iloc->partitionReferenceNum] could lead to
> bad memory access. See udf_nfs_get_inode() path for instance.
> 
> Signed-off-by: Fabian Frederick <f...@skynet.be>

Thanks. Applied.

                                                                Honza

> ---
>  fs/udf/inode.c | 6 ++++++
>  1 file changed, 6 insertions(+)
> 
> diff --git a/fs/udf/inode.c b/fs/udf/inode.c
> index 47638eb..3926973 100644
> --- a/fs/udf/inode.c
> +++ b/fs/udf/inode.c
> @@ -1276,6 +1276,12 @@ static int udf_read_inode(struct inode *inode, bool 
> hidden_inode)
>       int ret = -EIO;
>  
>  reread:
> +     if (iloc->partitionReferenceNum >= sbi->s_partitions) {
> +             udf_debug("partition reference: %d > logical volume partitions: 
> %d\n",
> +                       iloc->partitionReferenceNum, sbi->s_partitions);
> +             return -EIO;
> +     }
> +
>       if (iloc->logicalBlockNum >=
>           sbi->s_partmaps[iloc->partitionReferenceNum].s_partition_len) {
>               udf_debug("block=%d, partition=%d out of range\n",
> -- 
> 2.7.4
> 
> 
-- 
Jan Kara <j...@suse.com>
SUSE Labs, CR

Reply via email to