On Sun, Jan 22, 2017 at 01:23:07PM +0000, Jonathan Cameron wrote:
>On 19/01/17 15:06, William Breathitt Gray wrote:
>> The Apex Embedded Systems STX104 series provides a digital output
>> register where 4 lines may be set at a time. This patch add support for
>> the set_multiple callback function, thus allowing multiple digital
>> output lines to be set more efficiently in groups.
>> 
>> Cc: Jonathan Cameron <[email protected]>
>> Cc: Hartmut Knaack <[email protected]>
>> Cc: Lars-Peter Clausen <[email protected]>
>> Cc: Peter Meerwald-Stadler <[email protected]>
>> Signed-off-by: William Breathitt Gray <[email protected]>
>Acked-by: Jonathan Cameron <[email protected]>

Jonathan Cameron,

Would you pick this patch up in one of your iio.git branches?

Thanks,

William Breathitt Gray

Reply via email to