Hi,

On Saturday, March 11, 2017 07:25:22 PM Krzysztof Kozlowski wrote:
> The Exynos4412 has the same watchdog as newer SoCs (e.g. Exynos5250).
> Just like the others, for working it requires additional steps in Power
> Management Unit: unmasking the reset request and enabling the system
> reset.  Without these additional steps in PMU, the watchdog will not be
> able to reset the system on expiration event.
> 
> Change the compatible of Exynos4412 watchdog device node to
> samsung,exynos5250-wdt which includes the additional PMU steps.

This is going to confuse people.  How's about doing it cleanly
(by adding samsung,exynos4412-wdt compatible and convert existing
users to use instead)?

> This will also fix infinite watchdog interrupt in soft mode (lack of
> interrupt clear) because it is also included in samsung,exynos5250-wdt.
> 
> Signed-off-by: Krzysztof Kozlowski <k...@kernel.org>

Best regards,
--
Bartlomiej Zolnierkiewicz
Samsung R&D Institute Poland
Samsung Electronics