On Wed, Mar 22, 2017 at 06:53:07PM +0200, Leonard Crestez wrote:

> +     if (anatop_reg->bypass)
> +             anatop_reg->rdesc.min_dropout_uV = 0;
> +     else
> +             anatop_reg->rdesc.min_dropout_uV = LDO_MIN_DROPOUT_UV;

No, this is completely broken - you can't expect to randomly change hthe
regulator description at runtime behind the back of the framework and
expect things to work.  If there is a need to do this we need an
interface for getting the current value and a way to notify of changes.

That said I would not expect the dropout voltage to be considered at
all when the regulator is bypassed, since the regulator is not
regulating it doesn't need any headroom.