Florian Fainelli <[email protected]> writes: > On 04/24/2017 02:50 PM, Eric Anholt wrote: >> Cygnus has a single amac controller connected to the B53 switch with 2 >> PHYs. On the BCM911360_EP platform, those two PHYs are connected to >> the external ethernet jacks. >> >> Signed-off-by: Eric Anholt <[email protected]> > > This looks fine, just a few nits on the label names:
Thanks. I've applied all of these (and Andrew's and Scott's suggestions), and I'll send out a new version once the DT maintainers have had a chance to look.
signature.asc