ASC1 is available on every Lantiq SoC (also AmazonSE) and should be
enabled like the other generic xway clocks instead of ASC0, which is
only available for AR9 and Danube.

Signed-off-by: Martin Schiller <m...@dev.tdt.de>
---
 arch/mips/lantiq/xway/sysctrl.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)

diff --git a/arch/mips/lantiq/xway/sysctrl.c b/arch/mips/lantiq/xway/sysctrl.c
index 95bec46..cd6dbea 100644
--- a/arch/mips/lantiq/xway/sysctrl.c
+++ b/arch/mips/lantiq/xway/sysctrl.c
@@ -484,9 +484,9 @@ void __init ltq_soc_init(void)
 
        /* add our generic xway clocks */
        clkdev_add_pmu("10000000.fpi", NULL, 0, 0, PMU_FPI);
-       clkdev_add_pmu("1e100400.serial", NULL, 0, 0, PMU_ASC0);
        clkdev_add_pmu("1e100a00.gptu", NULL, 1, 0, PMU_GPT);
        clkdev_add_pmu("1e100bb0.stp", NULL, 1, 0, PMU_STP);
+       clkdev_add_pmu("1e100c00.serial", NULL, 0, 0, PMU_ASC1);
        clkdev_add_pmu("1e104100.dma", NULL, 1, 0, PMU_DMA);
        clkdev_add_pmu("1e100800.spi", NULL, 1, 0, PMU_SPI);
        clkdev_add_pmu("1e105300.ebu", NULL, 0, 0, PMU_EBU);
@@ -501,7 +501,6 @@ void __init ltq_soc_init(void)
        }
 
        if (!of_machine_is_compatible("lantiq,ase")) {
-               clkdev_add_pmu("1e100c00.serial", NULL, 0, 0, PMU_ASC1);
                clkdev_add_pci();
        }
 
-- 