On 06-07-17, 10:49, Dietmar Eggemann wrote:
> Implements an arch-specific frequency-scaling function
> topology_get_freq_scale() which provides the following frequency
> scaling factor:
> 
>   current_freq(cpu) << SCHED_CAPACITY_SHIFT / max_supported_freq(cpu)
> 
> One possible consumer of this is the Per-Entity Load Tracking (PELT)
> mechanism of the task scheduler.
> 
> Cc: Greg Kroah-Hartman <[email protected]>
> Cc: Juri Lelli <[email protected]>
> Signed-off-by: Dietmar Eggemann <[email protected]>
> ---
>  drivers/base/arch_topology.c  | 20 ++++++++++++++++++++
>  include/linux/arch_topology.h |  7 +++++++
>  2 files changed, 27 insertions(+)
> 
> diff --git a/drivers/base/arch_topology.c b/drivers/base/arch_topology.c
> index f4832c662762..63fb3f945d21 100644
> --- a/drivers/base/arch_topology.c
> +++ b/drivers/base/arch_topology.c
> @@ -22,6 +22,26 @@
>  #include <linux/string.h>
>  #include <linux/sched/topology.h>
>  
> +static DEFINE_PER_CPU(unsigned long, freq_scale) = SCHED_CAPACITY_SCALE;
> +
> +unsigned long topology_get_freq_scale(struct sched_domain *sd, int cpu)
> +{
> +     return per_cpu(freq_scale, cpu);
> +}
> +
> +void topology_set_freq_scale(struct cpumask *cpus, unsigned long cur_freq,
> +                          unsigned long max_freq)
> +{
> +     unsigned long scale;
> +     int i;
> +
> +     scale = (cur_freq << SCHED_CAPACITY_SHIFT) / max_freq;
> +
> +     for_each_cpu(i, cpus)
> +             per_cpu(freq_scale, i) = scale;
> +}
> +
> +
>  static DEFINE_MUTEX(cpu_scale_mutex);
>  static DEFINE_PER_CPU(unsigned long, cpu_scale) = SCHED_CAPACITY_SCALE;
>  
> diff --git a/include/linux/arch_topology.h b/include/linux/arch_topology.h
> index 9af3c174c03a..168104d2d2cf 100644
> --- a/include/linux/arch_topology.h
> +++ b/include/linux/arch_topology.h
> @@ -4,6 +4,8 @@
>  #ifndef _LINUX_ARCH_TOPOLOGY_H_
>  #define _LINUX_ARCH_TOPOLOGY_H_
>  
> +#include <linux/cpumask.h>
> +

You don't need a full include here, instead following will work pretty well.

struct cpumask;

>  void topology_normalize_cpu_scale(void);
>  
>  struct device_node;
> @@ -14,4 +16,9 @@ unsigned long topology_get_cpu_scale(struct sched_domain 
> *sd, int cpu);
>  
>  void topology_set_cpu_scale(unsigned int cpu, unsigned long capacity);
>  
> +unsigned long topology_get_freq_scale(struct sched_domain *sd, int cpu);
> +
> +void topology_set_freq_scale(struct cpumask *cpus, unsigned long cur_freq,
> +                          unsigned long max_freq);
> +
>  #endif /* _LINUX_ARCH_TOPOLOGY_H_ */

Apart from that:

Reviewed-by: Viresh Kumar <[email protected]>

-- 
viresh

Reply via email to