The I2C adapter driver is sometimes slow, causing the SCL line to
be stuck low for more than the stipulated SMBUS timeout of 25-35 ms.
This causes the client device to give up which in turn causes silent
corruption of data. So, disable the SMBUS timeout in the client device.

Signed-off-by: Peter Rosin <p...@axentia.se>
---
 arch/arm/boot/dts/at91-tse850-3.dts | 1 +
 1 file changed, 1 insertion(+)

diff --git a/arch/arm/boot/dts/at91-tse850-3.dts 
b/arch/arm/boot/dts/at91-tse850-3.dts
index 5f29010cdbd8..9b82cc8843e1 100644
--- a/arch/arm/boot/dts/at91-tse850-3.dts
+++ b/arch/arm/boot/dts/at91-tse850-3.dts
@@ -221,6 +221,7 @@
        jc42@18 {
                compatible = "nxp,se97b", "jedec,jc-42.4-temp";
                reg = <0x18>;
+               smbus-timeout-disable;
        };
 
        dpot: mcp4651-104@28 {
-- 
2.11.0