On Thu 30 Nov 17:52 PST 2017, Chris Lew wrote:

> 
> 
> On 11/29/2017 5:16 PM, Bjorn Andersson wrote:
> > The sysmon client communicates either via a dedicated SMD/GLINK channel
> > or via QMI encoded messages over IPCROUTER with remote processors in
> > order to perform graceful shutdown and inform about other remote
> > processors shutting down.
> > 
> > Signed-off-by: Bjorn Andersson <bjorn.anders...@linaro.org>
> > ---
> Acked-By: Chris Lew <c...@codeaurora.org>
> 

Thanks

> Looked into who is listening to the other notifications besides
> BEFORE_SHUTDOWN and I think subsequent patches will need to add support for
> at least AFTER_POWERUP.
> 

Agreed.

Regards,
Bjorn

Reply via email to