This adds documentation for the "backup" property of the axp20x driver,
that controls the charging mechanism for the backup battery on axp20x.

Signed-off-by: Paul Kocialkowski <[email protected]>

diff --git a/Documentation/devicetree/bindings/mfd/axp20x.txt 
b/Documentation/devicetree/bindings/mfd/axp20x.txt
index 9455503b0299..382776b29932 100644
--- a/Documentation/devicetree/bindings/mfd/axp20x.txt
+++ b/Documentation/devicetree/bindings/mfd/axp20x.txt
@@ -58,6 +58,11 @@ Optional properties:
              See Documentation/devicetree/bindings/regulator/regulator.txt
              for more information on standard regulator bindings.
 
+- backup: An array of two integers for backup battery charging (axp20x-only),
+         describing the charging voltage in mV first and the charging current
+         in uA second. Backup battery charging is only enabled when these two
+         fields are filled.
+
 Optional properties for DCDC regulators:
 - x-powers,dcdc-workmode: 1 for PWM mode, 0 for AUTO (PWM/PFM) mode
                          Default: Current hardware setting
@@ -256,4 +261,6 @@ axp209: pmic@34 {
                        /* unused but preferred to be managed by OS */
                };
        };
+
+       backup = <3000 200>;
 };
-- 