When update the clock info for the UART controller in the EE domain,
the driver explicitly require 'pclk' in order to work properly.

With current logic of the code, the driver will go for the legacy clock probe
routine[1] if it find current compatible string match to 'amlogic,meson-uart',
which result in not requesting the 'pclk' clock, thus break the driver in the 
end.

[1] drivers/tty/serial/meson_uart.c:685

        /* Use legacy way until all platforms switch to new bindings */
        if (of_device_is_compatible(pdev->dev.of_node, "amlogic,meson-uart"))
                ret = meson_uart_probe_clocks_legacy(pdev, port);
        else
                ret = meson_uart_probe_clocks(pdev, port);

Acked-by: Jerome Brunet <jbru...@baylibre.com>
Signed-off-by: Yixun Lan <yixun....@amlogic.com>
---
 arch/arm64/boot/dts/amlogic/meson-axg.dtsi | 8 ++++++--
 1 file changed, 6 insertions(+), 2 deletions(-)

diff --git a/arch/arm64/boot/dts/amlogic/meson-axg.dtsi 
b/arch/arm64/boot/dts/amlogic/meson-axg.dtsi
index 70c776ef7aa7..644d0f9eaf8c 100644
--- a/arch/arm64/boot/dts/amlogic/meson-axg.dtsi
+++ b/arch/arm64/boot/dts/amlogic/meson-axg.dtsi
@@ -164,17 +164,21 @@
                        };
 
                        uart_A: serial@24000 {
-                               compatible = "amlogic,meson-gx-uart", 
"amlogic,meson-uart";
+                               compatible = "amlogic,meson-gx-uart";
                                reg = <0x0 0x24000 0x0 0x18>;
                                interrupts = <GIC_SPI 26 IRQ_TYPE_EDGE_RISING>;
                                status = "disabled";
+                               clocks = <&xtal>, <&clkc CLKID_UART0>, <&xtal>;
+                               clock-names = "xtal", "pclk", "baud";
                        };
 
                        uart_B: serial@23000 {
-                               compatible = "amlogic,meson-gx-uart", 
"amlogic,meson-uart";
+                               compatible = "amlogic,meson-gx-uart";
                                reg = <0x0 0x23000 0x0 0x18>;
                                interrupts = <GIC_SPI 75 IRQ_TYPE_EDGE_RISING>;
                                status = "disabled";
+                               clocks = <&xtal>, <&clkc CLKID_UART1>, <&xtal>;
+                               clock-names = "xtal", "pclk", "baud";
                        };
                };
 
-- 
2.15.1