On Wed, Jan 31, 2018 at 10:35:44PM +0100, Benoît Thébaudeau wrote:
> The eSDHC does not work properly if the SION bit is not set for the
> bidirectional CMD signal, whatever the eSDHC instance and the selected
> pad. Therefore, setting SION is mandatory for all eSDHC CMD ports. Do
> this for MX25_PAD_*__ESDHCn_CMD in imx25-pinfunc.h in order to enforce
> this behavior for all boards.
> 
> This had already been done for eSDHC1, but not for eSDHC2. Also, define
> MX25_PAD_FEC_MDC__ESDHC2_CMD so that all the possible cases are covered
> from now on.
> 
> Cc: Uwe Kleine-König <[email protected]>
> Signed-off-by: Benoît Thébaudeau <[email protected]>
> Reviewed-by: Fabio Estevam <[email protected]>

Acked-by: Uwe Kleine-König <[email protected]>

Thanks
Uwe

-- 
Pengutronix e.K.                           | Uwe Kleine-König            |
Industrial Linux Solutions                 | http://www.pengutronix.de/  |