Hi, Le mercredi 11 avril 2018 à 08:28 +0200, Maxime Ripard a écrit : > On Tue, Apr 10, 2018 at 11:31:27PM +0200, Paul Kocialkowski wrote: > > This adds timings for the RGB666 variant of the Innolux AT070TN92 > > panel, > > as found on the Ainol AW1 tablet. > > > > Signed-off-by: Paul Kocialkowski <[email protected]> > > --- > > drivers/gpu/drm/panel/panel-simple.c | 26 > > ++++++++++++++++++++++++++ > > 1 file changed, 26 insertions(+) > > > > diff --git a/drivers/gpu/drm/panel/panel-simple.c > > b/drivers/gpu/drm/panel/panel-simple.c > > index 5591984a392b..efeb2f2162bc 100644 > > --- a/drivers/gpu/drm/panel/panel-simple.c > > +++ b/drivers/gpu/drm/panel/panel-simple.c > > @@ -1063,6 +1063,29 @@ static const struct panel_desc > > innolux_at070tn92 = { > > .bus_format = MEDIA_BUS_FMT_RGB888_1X24, > > }; > > > > +static const struct drm_display_mode innolux_at070tn92_rgb666_mode > > = { > > + .clock = 40000, > > + .hdisplay = 800, > > + .hsync_start = 800 + 112, > > + .hsync_end = 800 + 112 + 1, > > + .htotal = 800 + 112 + 1 + 87, > > + .vdisplay = 480, > > + .vsync_start = 480 + 141, > > + .vsync_end = 480 + 141 + 1, > > + .vtotal = 480 + 141 + 1 + 38, > > + .vrefresh = 60, > > +}; > > I'm not sure why you'd need different timings if the only difference > is the bus width.
I'll try with the other timings, although it might be desirable to have
a higher clock speed thanks to the reduced number of wires on the bus.
> > +static const struct panel_desc innolux_at070tn92_rgb666 = {
> > + .modes = &innolux_at070tn92_rgb666_mode,
> > + .num_modes = 1,
> > + .size = {
> > + .width = 154,
> > + .height = 86,
> > + },
> > + .bus_format = MEDIA_BUS_FMT_RGB666_1X18,
> > +};
> > +
> > static const struct display_timing innolux_g101ice_l01_timing = {
> > .pixelclock = { 60400000, 71100000, 74700000 },
> > .hactive = { 1280, 1280, 1280 },
> > @@ -2105,6 +2128,9 @@ static const struct of_device_id
> > platform_of_match[] = {
> > }, {
> > .compatible = "innolux,at070tn92",
> > .data = &innolux_at070tn92,
> > + }, {
> > + .compatible = "innolux,at070tn92-rgb666",
> > + .data = &innolux_at070tn92_rgb666,
>
> And this isn't a different device, it's just the integration in the
> board that is different, so you shouldn't have a different compatible
> here, but rather something like the bus-width property documented in
> the Documentation/devicetree/bindings/media/video-interfaces.txt file.
I'll take a look at it and try to craft v2 in this direction then.
Thanks for the review!
--
Paul Kocialkowski,
developer of free digital technology and hardware support.
Website: https://www.paulk.fr/
Coding blog: https://code.paulk.fr/
Git repositories: https://git.paulk.fr/ https://git.code.paulk.fr/
signature.asc
Description: This is a digitally signed message part