On Exynos4210 one-point trimming is always used and data->temp_error1
is equal to 75. Therefore temp_to_code() will never return negative
value for the reference temperature conversion.

There should be no functional changes caused by this patch.

Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnier...@samsung.com>
---
 drivers/thermal/samsung/exynos_tmu.c | 6 +-----
 1 file changed, 1 insertion(+), 5 deletions(-)

diff --git a/drivers/thermal/samsung/exynos_tmu.c 
b/drivers/thermal/samsung/exynos_tmu.c
index 58cd68e..26a0cb9 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -423,10 +423,6 @@ static int exynos4210_tmu_initialize(struct 
platform_device *pdev)
        /* Write temperature code for threshold */
        reference = trips[0].temperature / MCELSIUS;
        threshold_code = temp_to_code(data, reference);
-       if (threshold_code < 0) {
-               ret = threshold_code;
-               goto out;
-       }
        writeb(threshold_code, data->base + EXYNOS4210_TMU_REG_THRESHOLD_TEMP);
 
        for (i = 0; i < of_thermal_get_ntrips(tz); i++) {
@@ -436,7 +432,7 @@ static int exynos4210_tmu_initialize(struct platform_device 
*pdev)
        }
 
        data->tmu_clear_irqs(data);
-out:
+
        return ret;
 }
 
-- 
1.9.1