.report_temperature is not set in dra752_data which
results in temperature updates not being propagated by
ti_bandgap_talert_irq_handler() (it doesn't make much
sense to handle TALERT IRQ without reporting temperature
updates to the thermal core). Fix it.

Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnier...@samsung.com>
---
 drivers/thermal/ti-soc-thermal/dra752-thermal-data.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/thermal/ti-soc-thermal/dra752-thermal-data.c 
b/drivers/thermal/ti-soc-thermal/dra752-thermal-data.c
index 33a3030..e8ab7e5 100644
--- a/drivers/thermal/ti-soc-thermal/dra752-thermal-data.c
+++ b/drivers/thermal/ti-soc-thermal/dra752-thermal-data.c
@@ -338,6 +338,7 @@
        .adc_end_val = DRA752_ADC_END_VALUE,
        .expose_sensor = ti_thermal_expose_sensor,
        .remove_sensor = ti_thermal_remove_sensor,
+       .report_temperature = ti_thermal_report_sensor_temperature,
        .sensors = {
                {
                .registers = &dra752_mpu_temp_sensor_registers,
-- 
1.9.1

Reply via email to