On 5/23/2018 3:29 PM, Guenter Roeck wrote:
On Wed, May 23, 2018 at 01:32:03PM -0700, Ray Jui wrote:
Update the SP805 binding document to add optional 'timeout-sec'
devicetree property
Signed-off-by: Ray Jui <[email protected]>
Reviewed-by: Scott Branden <[email protected]>
Reviewed-by: Guenter Roeck <[email protected]>
---
Documentation/devicetree/bindings/watchdog/arm,sp805.txt | 2 ++
1 file changed, 2 insertions(+)
diff --git a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
index de93a4d..9cd7470 100644
--- a/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
+++ b/Documentation/devicetree/bindings/watchdog/arm,sp805.txt
@@ -18,6 +18,8 @@ Required properties:
Optional properties:
- interrupts : Should specify WDT interrupt number.
+timeout-sec : Should specify default WDT timeout in seconds. If unset, the
+ default timeout in the driver is 30 seconds
That looks odd, with the changed indentation and the missing '-'
in front of 'timeout-sec' >
My bad. Will fix this in v3. Thanks.
Guenter