The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Signed-off-by: Viresh Kumar <viresh.ku...@linaro.org>
---
 arch/arm/boot/dts/ls1021a.dtsi | 1 +
 1 file changed, 1 insertion(+)

diff --git a/arch/arm/boot/dts/ls1021a.dtsi b/arch/arm/boot/dts/ls1021a.dtsi
index c55d479971cc..f18490548c78 100644
--- a/arch/arm/boot/dts/ls1021a.dtsi
+++ b/arch/arm/boot/dts/ls1021a.dtsi
@@ -84,6 +84,7 @@
                        device_type = "cpu";
                        reg = <0xf01>;
                        clocks = <&clockgen 1 0>;
+                       #cooling-cells = <2>;
                };
        };
 
-- 
2.15.0.194.g9af6a3dea062