On Mon 2018-06-18 01:28:58, Tony Lindgren wrote:
> * Pavel Machek <pa...@ucw.cz> [180618 07:43]:
> > 
> > So... there are mA, mAh values. Those come from hardware, and I
> > believe we should keep them.
> > 
> > But there are also mW, mWh values, which are synthetic. Userland can
> > compute them from mV, mA values... and it is confusing that kernel
> > provides them. (My tendency was to start computing these synthetic
> > values in userland, to compare them with "real hardware" values from
> > kernel. But then I looked at kernel implementation, and realized they
> > are synthetic, tooo...)
> 
> Hmm mWh value is based on the hardware sampled shunt
> values and number of samples gathered between the
> two readings. I'd rather call the calculated values
> based on userland reading mV and mA values "synthetic" :)

As far as I know, shunt resistors provide you with current (mA) not
power (mW) measurement... and cpcap-battery computes power_now as
voltage * current. I'd rather have kernel tell me "hardware can't
measure power" and do "voltage*current" computation in userspace.

So I'm proposing to apply patch below.

Best regards,
                                                                Pavel


+++ b/drivers/power/supply/cpcap-battery.c
@@ -490,24 +490,6 @@ static int cpcap_battery_get_property(struct power_supply 
*psy,
        case POWER_SUPPLY_PROP_CHARGE_COUNTER:
                val->intval = latest->counter_uah;
                break;
-       case POWER_SUPPLY_PROP_POWER_NOW:
-               tmp = (latest->voltage / 10000) * latest->current_ua;
-               val->intval = div64_s64(tmp, 100);
-               break;
-       case POWER_SUPPLY_PROP_POWER_AVG:
-               if (cached) {
-                       tmp = cpcap_battery_cc_get_avg_current(ddata);
-                       tmp *= (latest->voltage / 10000);
-                       val->intval = div64_s64(tmp, 100);
-                       break;
-               }
-               sample = latest->cc.sample - previous->cc.sample;
-               accumulator = latest->cc.accumulator - previous->cc.accumulator;
-               tmp = cpcap_battery_cc_to_ua(ddata, sample, accumulator,
-                                            latest->cc.offset);
-               tmp *= ((latest->voltage + previous->voltage) / 20000);
-               val->intval = div64_s64(tmp, 100);
-               break;
        case POWER_SUPPLY_PROP_CAPACITY_LEVEL:
                if (cpcap_battery_full(ddata))
                        val->intval = POWER_SUPPLY_CAPACITY_LEVEL_FULL;

-- 
(english) http://www.livejournal.com/~pavelmachek