From: Viresh Kumar <viresh.ku...@linaro.org> [ Upstream commit 0c7f7a5150023f3c6f0b27c4d4940ce3dfaf62cc ]
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.ku...@linaro.org> Signed-off-by: Matthias Brugger <matthias....@gmail.com> Signed-off-by: Sasha Levin <alexander.le...@microsoft.com> --- arch/arm/boot/dts/mt7623.dtsi | 3 +++ 1 file changed, 3 insertions(+) diff --git a/arch/arm/boot/dts/mt7623.dtsi b/arch/arm/boot/dts/mt7623.dtsi index d1eb123bc73b..1cdc346a05e8 100644 --- a/arch/arm/boot/dts/mt7623.dtsi +++ b/arch/arm/boot/dts/mt7623.dtsi @@ -92,6 +92,7 @@ <&apmixedsys CLK_APMIXED_MAINPLL>; clock-names = "cpu", "intermediate"; operating-points-v2 = <&cpu_opp_table>; + #cooling-cells = <2>; clock-frequency = <1300000000>; }; @@ -103,6 +104,7 @@ <&apmixedsys CLK_APMIXED_MAINPLL>; clock-names = "cpu", "intermediate"; operating-points-v2 = <&cpu_opp_table>; + #cooling-cells = <2>; clock-frequency = <1300000000>; }; @@ -114,6 +116,7 @@ <&apmixedsys CLK_APMIXED_MAINPLL>; clock-names = "cpu", "intermediate"; operating-points-v2 = <&cpu_opp_table>; + #cooling-cells = <2>; clock-frequency = <1300000000>; }; }; -- 2.17.1