Add input voltage configuration options

Signed-off-by: Christian Hohnstaedt <christian.hohnsta...@wago.com>
---
 Documentation/devicetree/bindings/regulator/tps65218.txt | 10 ++++++++++
 1 file changed, 10 insertions(+)

diff --git a/Documentation/devicetree/bindings/regulator/tps65218.txt 
b/Documentation/devicetree/bindings/regulator/tps65218.txt
index 02f0e9b..a9ee377 100644
--- a/Documentation/devicetree/bindings/regulator/tps65218.txt
+++ b/Documentation/devicetree/bindings/regulator/tps65218.txt
@@ -16,12 +16,22 @@ Required properties:
   regulator-dcdc5, regulator-dcdc6, regulator-ldo1, regulator-ls3.
   Each regulator is defined using the standard binding for regulators.
 
+Optional properties:
+  If any of these properties is absent, the setting will not be touched.
+- strict-supply-voltage: <1|0> Set/Reset STRICT flag in CONFIG1
+- under-voltage-limit: Select 2.75, 2.95, 3.25 or 3.35V as UVLO in CONFIG1
+- under-voltage-hysteresis: Select 200mV or 400mV UVLOHYS in CONFIG2
+
 Example:
 tps65218: tps65218@24 {
        reg = <0x24>;
        compatible = "ti,tps65218";
        interrupts = <GIC_SPI 7 IRQ_TYPE_NONE>; /* NMIn */
        interrupt-controller;
+       strict-supply-voltage = <1>;
+       under-voltage-hysteresis = <400000>;
+       under-voltage-limit = <3350000>;
+
        #interrupt-cells = <2>;
 
        dcdc1: regulator-dcdc1 {
-- 
2.7.4