On 01/02/2019 08:38, michael....@mediatek.com wrote:
> From: Michael Kao <michael....@mediatek.com>
> 
> Add calibration item in thermal_data to support
> the project with different calibration coefficient.
> 
> Signed-off-by: Michael Kao <michael....@mediatek.com>
> ---
>  drivers/thermal/mtk_thermal.c | 19 ++++++++++++++++++-
>  1 file changed, 18 insertions(+), 1 deletion(-)
> 
> diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
> index 07f8ad7..45c6587 100644
> --- a/drivers/thermal/mtk_thermal.c
> +++ b/drivers/thermal/mtk_thermal.c
> @@ -105,6 +105,9 @@
>  /* The number of sensing points per bank */
>  #define MT8173_NUM_SENSORS_PER_ZONE  4
>  
> +/* The calibration coefficient of sensor  */
> +#define MT8173_CALIBRATION   165
> +

Calibration value is the same for all SoCs (including mt8183), we can define it
once and use it in all mtk_thermal structs.

Regards,
Matthias


>  /*
>   * Layout of the fuses providing the calibration data
>   * These macros could be used for MT8173, MT2701, and MT2712.
> @@ -147,6 +150,9 @@ enum {
>  /* The number of sensing points per bank */
>  #define MT2701_NUM_SENSORS_PER_ZONE  3
>  
> +/* The calibration coefficient of sensor  */
> +#define MT2701_CALIBRATION   165
> +
>  /* MT2712 thermal sensors */
>  #define MT2712_TS1   0
>  #define MT2712_TS2   1
> @@ -162,12 +168,18 @@ enum {
>  /* The number of sensing points per bank */
>  #define MT2712_NUM_SENSORS_PER_ZONE  4
>  
> +/* The calibration coefficient of sensor  */
> +#define MT2712_CALIBRATION   165
> +
>  #define MT7622_TEMP_AUXADC_CHANNEL   11
>  #define MT7622_NUM_SENSORS           1
>  #define MT7622_NUM_ZONES             1
>  #define MT7622_NUM_SENSORS_PER_ZONE  1
>  #define MT7622_TS1   0
>  
> +/* The calibration coefficient of sensor  */
> +#define MT7622_CALIBRATION   165
> +
>  struct mtk_thermal;
>  
>  struct thermal_bank_cfg {
> @@ -188,6 +200,7 @@ struct mtk_thermal_data {
>       const int *sensor_mux_values;
>       const int *msr;
>       const int *adcpnp;
> +     const int cali_val;
>       struct thermal_bank_cfg bank_data[];
>  };
>  
> @@ -295,6 +308,7 @@ struct mtk_thermal {
>       .num_banks = MT8173_NUM_ZONES,
>       .num_sensors = MT8173_NUM_SENSORS,
>       .vts_index = mt8173_vts_index,
> +     .cali_val = MT8173_CALIBRATION,
>       .bank_data = {
>               {
>                       .num_sensors = 2,
> @@ -330,6 +344,7 @@ struct mtk_thermal {
>       .num_banks = 1,
>       .num_sensors = MT2701_NUM_SENSORS,
>       .vts_index = mt2701_vts_index,
> +     .cali_val = MT2701_CALIBRATION,
>       .bank_data = {
>               {
>                       .num_sensors = 3,
> @@ -356,6 +371,7 @@ struct mtk_thermal {
>       .num_banks = 1,
>       .num_sensors = MT2712_NUM_SENSORS,
>       .vts_index = mt2712_vts_index,
> +     .cali_val = MT2712_CALIBRATION,
>       .bank_data = {
>               {
>                       .num_sensors = 4,
> @@ -376,6 +392,7 @@ struct mtk_thermal {
>       .num_banks = MT7622_NUM_ZONES,
>       .num_sensors = MT7622_NUM_SENSORS,
>       .vts_index = mt7622_vts_index,
> +     .cali_val = MT7622_CALIBRATION,
>       .bank_data = {
>               {
>                       .num_sensors = 1,
> @@ -402,7 +419,7 @@ static int raw_to_mcelsius(struct mtk_thermal *mt, int 
> sensno, s32 raw)
>       raw &= 0xfff;
>  
>       tmp = 203450520 << 3;
> -     tmp /= 165 + mt->o_slope;
> +     tmp /= mt->conf->cali_val + mt->o_slope;
>       tmp /= 10000 + mt->adc_ge;
>       tmp *= raw - mt->vts[sensno] - 3350;
>       tmp >>= 3;
> 

Reply via email to