Hi,

On 2/15/19 11:03 PM, Sven Van Asbroeck wrote:
The work which is scheduled on a POR boot is potentially left
pending or running until after the device module is removed,
which could result in a use-after-free.

Fix by registering a cancel/sync callback, which gets executed as
part of standard resource unwinding.

This issue was detected with the help of Coccinelle.

Cc: Hans de Goede <[email protected]>
Signed-off-by: Sven Van Asbroeck <[email protected]>

Looks good to me:

Reviewed-by: Hans de Goede <[email protected]>

Regards,

Hans


---
  drivers/power/supply/max17042_battery.c | 10 ++++++++++
  1 file changed, 10 insertions(+)

diff --git a/drivers/power/supply/max17042_battery.c 
b/drivers/power/supply/max17042_battery.c
index 2a8d75e5e930..581c6bd23388 100644
--- a/drivers/power/supply/max17042_battery.c
+++ b/drivers/power/supply/max17042_battery.c
@@ -995,6 +995,13 @@ static const struct power_supply_desc 
max17042_no_current_sense_psy_desc = {
        .num_properties = ARRAY_SIZE(max17042_battery_props) - 2,
  };
+static void max17042_stop_work(void *data)
+{
+       struct max17042_chip *chip = data;
+
+       cancel_work_sync(&chip->work);
+}
+
  static int max17042_probe(struct i2c_client *client,
                        const struct i2c_device_id *id)
  {
@@ -1101,6 +1108,9 @@ static int max17042_probe(struct i2c_client *client,
        regmap_read(chip->regmap, MAX17042_STATUS, &val);
        if (val & STATUS_POR_BIT) {
                INIT_WORK(&chip->work, max17042_init_worker);
+               ret = devm_add_action(&client->dev, max17042_stop_work, chip);
+               if (ret)
+                       return ret;
                schedule_work(&chip->work);
        } else {
                chip->init_complete = 1;

Reply via email to