From: Mike Looijmans <mike.looijm...@topic.nl>

commit 9436f45dd53595e21566a8c6627411077dfdb776 upstream.

The standard unit for temperature is millidegrees Celcius. Adapt the
driver to report in millidegrees instead of degrees.

Signed-off-by: Mike Looijmans <mike.looijm...@topic.nl>
Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor");
Cc: <sta...@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jonathan.came...@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gre...@linuxfoundation.org>

---
 drivers/iio/chemical/bme680_core.c |   16 +++++++---------
 1 file changed, 7 insertions(+), 9 deletions(-)

--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -591,8 +591,7 @@ static int bme680_gas_config(struct bme6
        return ret;
 }
 
-static int bme680_read_temp(struct bme680_data *data,
-                           int *val, int *val2)
+static int bme680_read_temp(struct bme680_data *data, int *val)
 {
        struct device *dev = regmap_get_device(data->regmap);
        int ret;
@@ -625,10 +624,9 @@ static int bme680_read_temp(struct bme68
         * compensate_press/compensate_humid to get compensated
         * pressure/humidity readings.
         */
-       if (val && val2) {
-               *val = comp_temp;
-               *val2 = 100;
-               return IIO_VAL_FRACTIONAL;
+       if (val) {
+               *val = comp_temp * 10; /* Centidegrees to millidegrees */
+               return IIO_VAL_INT;
        }
 
        return ret;
@@ -643,7 +641,7 @@ static int bme680_read_press(struct bme6
        s32 adc_press;
 
        /* Read and compensate temperature to get a reading of t_fine */
-       ret = bme680_read_temp(data, NULL, NULL);
+       ret = bme680_read_temp(data, NULL);
        if (ret < 0)
                return ret;
 
@@ -676,7 +674,7 @@ static int bme680_read_humid(struct bme6
        u32 comp_humidity;
 
        /* Read and compensate temperature to get a reading of t_fine */
-       ret = bme680_read_temp(data, NULL, NULL);
+       ret = bme680_read_temp(data, NULL);
        if (ret < 0)
                return ret;
 
@@ -769,7 +767,7 @@ static int bme680_read_raw(struct iio_de
        case IIO_CHAN_INFO_PROCESSED:
                switch (chan->type) {
                case IIO_TEMP:
-                       return bme680_read_temp(data, val, val2);
+                       return bme680_read_temp(data, val);
                case IIO_PRESSURE:
                        return bme680_read_press(data, val, val2);
                case IIO_HUMIDITYRELATIVE:


Reply via email to