On 16/05/19 6:18 PM, Axel Lin wrote:
> A NULL init_data once incremented will lead to oops, fix it.
> 
> Fixes: f979c08f7624 ("regulator: tps6507x: Convert to regulator core's 
> simplified DT parsing code")
> Reported-by: Sekhar Nori <nsek...@ti.com>
> Signed-off-by: Axel Lin <axel....@ingics.com>
> ---
> Hi Sekhar,
> Please check if this patch works, thanks.
> Axel

Boot is fine now and PMIC regulator rail microvolts readings from sysfs
are correct as well. I did not try to change the voltages though.

Tested-by: Sekhar Nori <nsek...@ti.com>

Thanks,
Sekhar

Reply via email to