From: Hans de Goede <hdego...@redhat.com>

[ Upstream commit 3d0818f5eba80fbe4c0addbfe6ddb2d19dc82cd4 ]

The Lex 3I380D industrial PC has 4 ethernet controllers on board
which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems
DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks
as CLK_CRITICAL and they will not get turned off.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Reported-and-tested-by: Semyon Verchenko <semverche...@factor-ts.ru>
Signed-off-by: Hans de Goede <hdego...@redhat.com>
Acked-by: Andy Shevchenko <andy.shevche...@gmail.com>
Signed-off-by: Andy Shevchenko <andriy.shevche...@linux.intel.com>
Signed-off-by: Sasha Levin <sas...@kernel.org>
---
 drivers/platform/x86/pmc_atom.c | 9 +++++++++
 1 file changed, 9 insertions(+)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index c7039f52ad51..a311f48ce7c9 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -398,12 +398,21 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc)
  */
 static const struct dmi_system_id critclk_systems[] = {
        {
+               /* pmc_plt_clk0 is used for an external HSIC USB HUB */
                .ident = "MPL CEC1x",
                .matches = {
                        DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
                        DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
                },
        },
+       {
+               /* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
+               .ident = "Lex 3I380D",
+               .matches = {
+                       DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
+                       DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
+               },
+       },
        { /*sentinel*/ }
 };
 
-- 
2.20.1

Reply via email to