Add documentation for 'xlnx,zynqmp-8.9a' SDHCI controller and optional
properties followed by example.

Signed-off-by: Manish Narani <manish.nar...@xilinx.com>
---
 .../devicetree/bindings/mmc/arasan,sdhci.txt       | 32 ++++++++++++++++++++++
 1 file changed, 32 insertions(+)

diff --git a/Documentation/devicetree/bindings/mmc/arasan,sdhci.txt 
b/Documentation/devicetree/bindings/mmc/arasan,sdhci.txt
index 1edbb04..6945b3b 100644
--- a/Documentation/devicetree/bindings/mmc/arasan,sdhci.txt
+++ b/Documentation/devicetree/bindings/mmc/arasan,sdhci.txt
@@ -15,6 +15,9 @@ Required Properties:
     - "arasan,sdhci-5.1": generic Arasan SDHCI 5.1 PHY
     - "rockchip,rk3399-sdhci-5.1", "arasan,sdhci-5.1": rk3399 eMMC PHY
       For this device it is strongly suggested to include 
arasan,soc-ctl-syscon.
+    - "xlnx,zynqmp-8.9a": ZynqMP SDHCI 8.9a PHY
+      For this device it is strongly suggested to include clock-output-names 
and
+      #clock-cells.
     - "ti,am654-sdhci-5.1", "arasan,sdhci-5.1": TI AM654 MMC PHY
        Note: This binding has been deprecated and moved to [5].
 
@@ -45,6 +48,24 @@ Optional Properties:
   - xlnx,int-clock-stable-broken: when present, the controller always reports
     that the internal clock is stable even when it is not.
 
+Optional Properties for "xlnx,zynqmp-8.9a":
+  - xlnx,tap-delay-mmc-hsd: Input/Output Tap Delays in degrees for MMC HS.
+  - xlnx,tap-delay-sd-hsd: Input/Output Tap Delays in degrees for SD HS.
+  - xlnx,tap-delay-sdr25: Input/Output Tap Delays in degrees for SDR25.
+  - xlnx,tap-delay-sdr50: Input/Output Tap Delays in degrees for SDR50.
+  - xlnx,tap-delay-sdr104: Input/Output Tap Delays in degrees for SDR104.
+  - xlnx,tap-delay-sd-ddr50: Input/Output Tap Delays in degrees for SD DDR50.
+  - xlnx,tap-delay-mmc-ddr52: Input/Output Tap Delays in degrees for MMC DDR52.
+  - xlnx,tap-delay-mmc-hs200: Input/Output Tap Delays in degrees for MMC HS200.
+
+  Above mentioned are the clock (phase) delays which are to be configured in 
the
+  controller while switching to particular speed mode. If not specified, driver
+  will configure the default value defined for particular mode in it.
+
+  - xlnx,mio-bank: When specified, this will indicate the MIO bank number in
+    which the command and data lines are configured. If not specified, driver
+    will assume this as 0.
+
 Example:
        sdhci@e0100000 {
                compatible = "arasan,sdhci-8.9a";
@@ -80,3 +101,14 @@ Example:
                phy-names = "phy_arasan";
                #clock-cells = <0>;
        };
+
+       sdhci: mmc@ff160000 {
+               compatible = "xlnx,zynqmp-8.9a", "arasan,sdhci-8.9a";
+               interrupt-parent = <&gic>;
+               interrupts = <0 48 4>;
+               reg = <0x0 0xff160000 0x0 0x1000>;
+               clock-names = "clk_xin", "clk_ahb";
+               clock-output-names = "clk_sd0";
+               #clock-cells = <0>;
+               xlnx,tap-delay-sd-hsd = <21>, <6>;
+       };
-- 
2.1.1