Since the ad193x codecs have no software reset, we have to reinitialize the
registers after a hardware reset. For example, if we change the
device-tree between these resets, changing the audio format of the DAI link
from DSP_A with 8 TDM channels to I2S 2 channels, DAC Control 1 register
will remain configured for 8 channels. This patch resets this register at
probe to its default value.

Signed-off-by: Codrin Ciubotariu <codrin.ciubota...@microchip.com>
---
 sound/soc/codecs/ad193x.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/sound/soc/codecs/ad193x.c b/sound/soc/codecs/ad193x.c
index 3ebc0524f4b2..cda435562a1d 100644
--- a/sound/soc/codecs/ad193x.c
+++ b/sound/soc/codecs/ad193x.c
@@ -427,6 +427,8 @@ static int ad193x_component_probe(struct snd_soc_component 
*component)
        regmap_write(ad193x->regmap, AD193X_DAC_CTRL2, 0x1A);
        /* dac in tdm mode */
        regmap_write(ad193x->regmap, AD193X_DAC_CTRL0, 0x40);
+       /* reset DAC ctrl1 */
+       regmap_write(ad193x->regmap, AD193X_DAC_CTRL1, 0x00);
 
        /* adc only */
        if (ad193x_has_adc(ad193x)) {
-- 
2.20.1