On Sat, Jul 06, 2019 at 02:44:03PM +0200, Jernej Škrabec wrote: > Dne sobota, 06. julij 2019 ob 13:21:44 CEST je Mark Brown napisal(a):
> > This is not a great changelog - what are the bugs and how does > > this patch fix them? > In case of DCDCA, number of steps for second range should be 20 (0x14), but > it > was set to 14. So I guess patch author missed "0x". Currently, math doesn't > work, because sum of both number of steps plus 2 must be equal to number of > voltages macro. > Same error is present in AXP803 DCDC6 regulator. > In case of DCDCD, array of ranges (axp806_dcdcd_ranges) contains two ranges, > which use same start and end macros. By checking datasheet or just checking > macros at the top of the source file, it's obvious that "1" is missing in > second range macro names (1600 instead of 600). Can you please resend these with changelogs on the relevant patches so they can be reviewed more sensibly?