On 7/17/19 12:10 PM, Krzysztof Kozlowski wrote:
> On Mon, 15 Jul 2019 at 14:44, Lukasz Luba <l.l...@partner.samsung.com> wrote:
>>
>> The NOC100 has a parent which clock rate is set tot 400MHz. The OPPs which
>> are not possible to set are removed and new one is added.
> 
> I think it is just NOC bus... or are there more of such and this is 100 MHz 
> one?
Yes, there is a bus NOC100 with a dedicated clock tree in the HW (with
3 muxes and one divider), which makes possible to take different PLL as
a source then WCORE have, divide the rate from it and even switch for a
while to alternative stable PLL (on the 2nd mux to SPLL (after a
divider)) to wait for main PLL rate change stability delay. Max rate is
limited to 100MHz for this NOC100 bus.

Regards,
Lukasz
> 
> Best regards,
> Krzysztof
> 
> 

Reply via email to