On 26/07/2019 00:18, Amit Kucheria wrote:
> There are two fields - id and hw_id - to track what sensor an action was
> to performed on. This was because the sensors connected to a TSENS IP
> might not be contiguous i.e. 1, 2, 4, 5 with 3 being skipped.
> 
> This causes confusion in the code which uses hw_id sometimes and id
> other times (tsens_get_temp, tsens_get_trend).
> 
> Switch to only using the hw_id field to track the physical ID of the
> sensor. When we iterate through all the sensors connected to an IP
> block, we use an index i to loop through the list of sensors, and then
> return the actual hw_id that is registered on that index.
> 
> Signed-off-by: Amit Kucheria <amit.kuche...@linaro.org>

Reviewed-by: Daniel Lezcano <daniel.lezc...@linaro.org>




-- 
 <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog

Reply via email to