On Tue, Aug 20, 2019 at 06:39:36PM -0700, Andrey Smirnov wrote:
> Fiber-optic modules attached to the bus are only rated to work at
> 100 kHz, so decrease the bus frequency to accommodate that.
> 
> Signed-off-by: Andrey Smirnov <[email protected]>
> Cc: Shawn Guo <[email protected]>
> Cc: Chris Healy <[email protected]>
> Cc: Fabio Estevam <[email protected]>
> Cc: [email protected]
> Cc: [email protected]

Applied, thanks.

Reply via email to