Introduce a new binding parameter to thermal trip point description
to indicate whether the temperature level specified by the trip point
is monitored for a rise or fall in temperature.

Signed-off-by: Thara Gopinath <thara.gopin...@linaro.org>
---
 Documentation/devicetree/bindings/thermal/thermal.txt | 8 ++++++++
 1 file changed, 8 insertions(+)

diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt 
b/Documentation/devicetree/bindings/thermal/thermal.txt
index ca14ba9..849a2a9 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -90,6 +90,14 @@ Required properties:
        "critical":     Hardware not reliable.
   Type: string
 
+Optional property:
+- monitor-falling:     Indicate whether the system action is kick
+  Type: boolean                started when the temperature falls below or 
rises
+                       above the trip temperature level indicated in
+                       "temperature".If true, the trip point is monitored
+                       for falling temperature else the trip point is
+                       monitored for rising temperature.
+
 * Cooling device maps
 
 The cooling device maps node is a node to describe how cooling devices
-- 
2.1.4