On Fri, Sep 27, 2019 at 12:44:55PM +0000, Benjamin GAIGNARD wrote:
[...]
>
> Even in low-power modes this timer is always powered and clocked so it
> is working fine.
>
Is that tested ? I see only cpu_{on,off} available on this platform with
PSCI v0.1. Did you add cpu_suspend, idle-states and then gave it a spin ?
Or do you have some other idle driver with which this is tested ?
Also I don't understand how "always-on" is linked to hrtimer. Always on
timers are just selected to be broadcast timer without sacrificing(simply
keeping) a cpu to be always active for broadcast purposes.
--
Regards,
Sudeep