From: Fabrice Gasnier <fabrice.gasn...@st.com>

[ Upstream commit c91e3234c6035baf5a79763cb4fcd5d23ce75c2b ]

LPTimer can use a 32KHz clock for counting. It depends on clock tree
configuration. In such a case, PWM output frequency range is limited.
Although unlikely, nothing prevents user from requesting a PWM frequency
above counting clock (32KHz for instance):
- This causes (prd - 1) = 0xffff to be written in ARR register later in
the apply() routine.
This results in badly configured PWM period (and also duty_cycle).
Add a check to report an error is such a case.

Signed-off-by: Fabrice Gasnier <fabrice.gasn...@st.com>
Reviewed-by: Uwe Kleine-König <u.kleine-koe...@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.red...@gmail.com>
Signed-off-by: Sasha Levin <sas...@kernel.org>
---
 drivers/pwm/pwm-stm32-lp.c | 6 ++++++
 1 file changed, 6 insertions(+)

diff --git a/drivers/pwm/pwm-stm32-lp.c b/drivers/pwm/pwm-stm32-lp.c
index 2211a642066db..97a9afa191ee0 100644
--- a/drivers/pwm/pwm-stm32-lp.c
+++ b/drivers/pwm/pwm-stm32-lp.c
@@ -59,6 +59,12 @@ static int stm32_pwm_lp_apply(struct pwm_chip *chip, struct 
pwm_device *pwm,
        /* Calculate the period and prescaler value */
        div = (unsigned long long)clk_get_rate(priv->clk) * state->period;
        do_div(div, NSEC_PER_SEC);
+       if (!div) {
+               /* Clock is too slow to achieve requested period. */
+               dev_dbg(priv->chip.dev, "Can't reach %u ns\n",  state->period);
+               return -EINVAL;
+       }
+
        prd = div;
        while (div > STM32_LPTIM_MAX_ARR) {
                presc++;
-- 
2.20.1