Output of humidity compensation is limited to the range between 0 and
100 percent. Add this to the compensation formula as described in the
datasheet chapter 4.2.3.

Change to v1:
Thanks to Tomasz for suggesting the easier to use function clamp_val()
which is now used.

Signed-off-by: Andreas Klinger <a...@it-klinger.de>
---
 drivers/iio/pressure/bmp280-core.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/drivers/iio/pressure/bmp280-core.c 
b/drivers/iio/pressure/bmp280-core.c
index 29c209cc1108..297ee2205bf6 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -271,6 +271,8 @@ static u32 bmp280_compensate_humidity(struct bmp280_data 
*data,
                + (s32)2097152) * calib->H2 + 8192) >> 14);
        var -= ((((var >> 15) * (var >> 15)) >> 7) * (s32)calib->H1) >> 4;
 
+       var = clamp_val(var, 0, 419430400);
+
        return var >> 12;
 };
 
-- 