On Mon, May 04, 2020 at 09:47:48PM +0200, Michał Mirosław wrote:
> Document newly introduced IBAT compensation settings.
> 
> Signed-off-by: Michał Mirosław <mirq-li...@rere.qmqm.pl>
> ---
> v2: initial version
> ---
>  Documentation/devicetree/bindings/power/supply/bq25890.txt | 4 ++++
>  1 file changed, 4 insertions(+)
> 
> diff --git a/Documentation/devicetree/bindings/power/supply/bq25890.txt 
> b/Documentation/devicetree/bindings/power/supply/bq25890.txt
> index dc9c8f76e06c..bd214945d9dc 100644
> --- a/Documentation/devicetree/bindings/power/supply/bq25890.txt
> +++ b/Documentation/devicetree/bindings/power/supply/bq25890.txt
> @@ -32,6 +32,10 @@ Optional properties:
>  - ti,thermal-regulation-threshold: integer, temperature above which the 
> charge
>      current is lowered, to avoid overheating (in degrees Celsius). If 
> omitted,
>      the default setting will be used (120 degrees);
> +- ti,ibatcomp-resistance: integer, value of a resistor in series with
> +    the battery (in uOhm);
> +- ti,ibatcomp-clamp-voltage: integer, maximum charging voltage adjustment due
> +    to expected voltage drop on in-series resistor (in uV);

Need a unit suffix as defined in property-units.txt

Rob