A battery, that is neither charged, nor discharged is not
always Full. If the charger is disabled for other reasons
it might simply be idle and should be marked accordingly.

Signed-off-by: Sebastian Reichel <sebastian.reic...@collabora.com>
---
 drivers/power/supply/sbs-battery.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/power/supply/sbs-battery.c 
b/drivers/power/supply/sbs-battery.c
index 2a2b926ad75c..e3c685b2c247 100644
--- a/drivers/power/supply/sbs-battery.c
+++ b/drivers/power/supply/sbs-battery.c
@@ -354,9 +354,9 @@ static int sbs_status_correct(struct i2c_client *client, 
int *intval)
 
        ret = (s16)ret;
 
-       /* Not drawing current means full (cannot be not charging) */
-       if (ret == 0)
-               *intval = POWER_SUPPLY_STATUS_FULL;
+       /* Not drawing current -> not charging (i.e. idle) */
+       if (*intval != POWER_SUPPLY_STATUS_FULL && ret == 0)
+               *intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
 
        if (*intval == POWER_SUPPLY_STATUS_FULL) {
                /* Drawing or providing current when full */
-- 
2.26.2

Reply via email to